UrbanStone Commercial
Search

UrbanStone Commercial Paving Specification


Material Standards


  • Cement
    Cement shall comply with AS 3972 - 1991 Portland and Blended Cements.
  • Aggregates
    Aggregates shall comply with AS 2758.1 - 1985 Concrete Aggregates.
  • Admixtures
    Admixtures shall comply with AS 1478 - 1992 Chemical Admixtures for Concrete.
  • Pigments
    Pigments shall comply with BS 1014 Pigments for Portland Cement & Portland Cement Products.
  • Water
    Water should be free of injurious quantities of material harmful to concrete.

Back to top

Paving Units


Colour


Specify UrbanStone Commercial colours stating colour name, mix code and unit size. Current standard colours include:

Colour Name Mix Code
Gunmetal 206
Silvergrey 100
Granite Cream 789
PCC Grey 700
New Amber 209
Topaz 461
Ivory 510
Granite Bronze 748
Ochre 702
Casino Grey 924
Golden Gunmetal 777

Back to top

Pigmentation & Aggregate


Pigmentation and surface aggregate shall be uniform throughout the full thickness of the paving unit.

Back to top

Surface finish


Surface Finish is to be specified as follows:

  • Shotblast
  • Milled
  • Honed Grit 120
  • Honed/Shotblast
  • Polished

If a unit is larger than 600 x 600 a Sandblast finish will replace the Shotblast Finish. The exposed aggregate content of the surface should be a minimum of 80 percent and no aggregate should have more than 30 percent of its grading protruding above the surface of the cement matrix.

Back to top

Dimensions


  • Thickness
    The thickness of any unit should be within +/- 3mm of the designated thickness, except where honing or polishing is specified as this may reduce the paving nominal thickness.
  • Length and Width
    The length and width of any unit should be no greater than the overall nominal dimensions and within 1.5mm less than the stated nominal dimensions.
  • Draw
    Units should be straight-sided with zero taper.
  • Flatness and Bowing
    The maximum deviation from a 350mm straight edge, placed in any central position on the wearing surface of each individual unit, should not exceed 3.5mm.
  • Chamfer
    The arises of the off form paving unit should have a rounded edge with a radius not exceeding the maximum aggregate size used (nominally 4.5mm radius) prior to secondary or tertiary treatment (ie shotblasting or honing).
  • Compressive Strength
    The minimum twenty-eight day characteristic strength shall be >35Mpa
  • Breaking Load
    The minimum breaking load of paving units sampled from lots shall be 4kN for 40mm thick units and 5kN for 60mm thick units.
  • Slip Resistance
    Slip Resistance of new shotblast product shall have a classification of 'V' (very low risk of slip when wet).
    Slip Resistance of new milled product shall have a classification of 'W' (low risk of slip when wet).
    Slip Resistance of new honed product shall have a classification of 'X' (moderate risk of slip when wet).
    Slip Resistance of new honed/shotblast product shall have a classification of 'W' (low risk of slip when wet).
  • Abrasion Resistance
    The Mean Abrasion Index shall be determined in accordance with AS/NZS 4456.9. - Masonry Units and Segmental Pavers - Method of Test, and will be no greater than 3.0 for units to be installed in high volume pedestrian malls.

Back to top

UrbanStone Commercial Furniture and Landscape Accessories Specification


Material Standards


  • Cement
    Cement shall comply with AS 3972 - 1991 Portland and Blended Cements.
  • Aggregates
    Aggregates shall comply with AS 2758.1 - 1985 Concrete Aggregates.
  • Admixtures
    Admixtures shall comply with AS 1478 - 1992 Chemical Admixtures for Concrete.
  • Pigments
    Pigments shall comply with BS 1014 Pigments for Portland Cement & Portland Cement Products.
  • Water
    Water should be free of injurious quantities of material harmful to concrete.

Back to top

Furniture and Landscaping Units


Colour


Specify UrbanStone Commercial colours stating colour name and mix code. Current standard colours include:

Colour Name Mix Code
Gunmetal 206
Silvergrey 100
Granite Cream 789
PCC Grey 700
New Amber 209
Topaz 461
Ivory 510
Granite Bronze 748
Ochre 702
Casino Grey 924
Golden Gunmetal 777

Back to top

Pigmentation and Aggregate


Pigmentation and surface aggregate shall be uniform throughout the full thickness of the precast unit.

Back to top

Surface Finish


Surface Finish is to be specified as follows:

  • Sandblast
  • Milled
  • Honed Grit 120
  • Polished

Back to top

Dimensions


  • Thickness
    The thickness of any unit should be within +/- 5mm of the designated thickness.
  • Length and Width
    The length and width of any unit should be within +/-5mm of the designated dimensions.
  • Draw
    Units should have minimal draw to allow for stripping.
  • Compressive Strength
    The minimum twenty-eight day characteristic strength shall be 40Mpa.

Back to top

Chemical Coatings


  • Anti-Graffiti
    A gloss or matt finish anti graffiti coating should be specified, if required.
  • Water proof
    A transparent waterproof coating should be specified, if required.

Back to top

Chemical Coatings


Shop Drawings

Precast units will only be manufactured after the client has approved detailed shop drawings. Note: To help in ensuring the accuracy of quotations it is advisable to submit as much detail as possible in the form of a sketch or drawing. Remember, the less information available the slower the process will be.

Back to top

Samples


Samples of colours and finishes are available for the client’s approval. Precast units will only be manufactured after the client has approved the colour and finish to be supplied.

Note: If your project has a short lead time, allow sufficient time for sample approval. It is better to get precisely what you want, the first time your request is addressed.

Back to top